Heat Meters & Heat Cost Allocators

Published 2026-11-23

End product

Heat meters and heat cost allocators measure the heat consumed by a heating system.

How it works

Heating water drives a magnetic impeller in the integrator. A Hall sensor reads the impeller speed and outputs flow pulses, which are combined with the supply/return temperature difference to calculate heat.

Selection considerations

Water temperature is commonly 70~90°C during the heating season, and the device may sit idle for long periods outside it. Low temperature drift and very low standby current are required.

Ouzhuo solution

Wide-temperature, low-power omnipolar Hall ICs (-40~125°C) suited to long-term meter operation; final accuracy is calibrated on the complete meter.

Typical structure and mounting notes

A heat meter usually consists of a flow meter, supply and return temperature sensors and a calculator: a magnet on the impeller works with a Hall sensor to output flow pulses, two temperature probes measure supply and return temperatures, and the calculator integrates heat from flow, temperature difference and the medium’s specific heat. A heat cost allocator measures radiator surface temperature and apportions heat using empirical coefficients, usually without a flow meter. The Hall sensor here only provides flow pulses or position detection; temperature is measured by independent probes.

Place the magnets symmetrically and balance the impeller, fix the Hall sensor outside the meter body cavity, and let the wall thickness define the air gap. The temperature probe insertion depth must represent the fluid temperature, with good thermal contact to the pipe. Heating water is commonly 70~90°C, so choose a temperature-rated magnet and include Hall operating-point drift in calibration. Outside the heating season the device is idle for long periods, so consider condensation, battery self-discharge and seal aging.

Heat-meter accuracy depends on flow, temperature difference and integration; an error in any part adds to the heat reading. During selection, check the Hall temperature range, quiescent current and operating-point consistency together. For a broader description of the structure and troubleshooting, see Heat Meter Flow & Temperature Measurement, and for the flow-pulse part see Flow Metering. Confirm the specific accuracy class and verification requirements against the meter specification.

FAQ

  • Heat reading is low or does not accumulate: first check whether flow pulses are missing, then whether the supply/return probes are reversed or poorly connected.
  • Flow is normal but heat deviates: verify temperature-difference measurement, medium specific-heat parameters and the integration formula settings.
  • Counting is abnormal at high heating-season temperature: check magnet temperature rating, Hall temperature drift and potting stress at high temperature.
  • First start-up after the off-season is abnormal: check condensation, battery voltage and seal aging.
  • Allocation results differ within a batch: check temperature-probe consistency, mounting position and allocation coefficients.